K120S

Powerful & compact block-type PLC CPU, digital I/O and power part are embedded in block-type PLCs, which is very compact and easy to install in area you want for system configuration. Also through various built-in function, user can configure cost-effective system.
Features
K80S Features
Compact and high-function block type
- Base: 10, 20, 30, 40, 60 points
- Expansion: 10, 20 points
Various built-in functions for applications
- HSC 1 point, Pulse output 1 point
- PID (Max. 8 loops), Pulse catch 8 points
- Built-in RS-232C I/F 1Ch: 4 (Rx), 7 (Tx), 5 (SG)
Various applications with special/comm. modules
- Analog input/output: G7F-ADHA
- Analog input: G7F-AD2A
- Analog timer: G7F-AT2A
- Cnet I/F: RS-232C, RS-422
- Fnet (Master)/Rnet (Master)
- Profibus-DP (Slave)/DeviceNet (Slave)
- RTC/Memory pack
On-line edit in KGL WIN
K120S Features
High-performance and various block type
- Economic type: 10/14/20/30 points (10/14 points: 2points built-in Analog Timer)
- Standard type: 20/30/40/60 points
- Various expansion modules: input, output, mixed modules
- P area extended for SMART I/O application (P000~P63F)
- High-speed processing speed: 0.1㎲/step (standard type)
- Battery-less backup
- Program backup: EEPROM backup while online editing
- Data backup: Super capacitor
- Various input handing: Input filter, pulse catch
Enhanced communication functions
- Built-in RS-232C (Ch0) and RS-485 (Ch1) support *1)
- Transmitting data monitoring support: KGLWIN
- Various option modules
- Cnet (RS-232C, RS-422) Fnet/Rnet (master module)
- Profibus-DP/DeviceNet (slave module)
Powerful built-in functions
- High-speed counter: 32-bit signed operation
- Counter range: -2,147,483,648 ~ 2,147,483,647
- Function: ring counter, latch counter, comparison (equal/zone/task), RPM
- Positioning function (DRT/DT type)
- Control axis: 2 axes (100kHz)
- Operation method: single, repeat
- Operation mode: end, keep, continuous
- Additional functions: return to origin, JOG operation, PWM output
- PID operation function
- Relay/PRC auto-tuning, SV ramp, delta MV, PWM output, position/velocity algorithm
Various expansion modules
- 7 Digital I/O modules: G7E-DR(08/10/20)A, G7E-TR10A, G7E-DC08A, G7E-RY(08/16)A
- 9 Analog I/O modules: G7F-ADHA(B/C), G7F-AD2A(B), G7F-DA2I(V), G7F-AT2A, G7F-RD2A
- 6 Comm. modules: G7L-CUEB(C), G7L-DBEA, G7L-PBEA, G7L-FUEA, G7L-RUEA
- 2 Option modules: G7E-RTCA, G7M-M256B
Specification
K80S System Specifications
K80S System Specifications
Item |
Specifications |
Operation method |
Cyclic execution of stored program, Time-driven operation, Interrupt task execution |
Program language |
Mnemonic, Ladder |
I/O control method |
Scan synchronized batch processing method (Refresh method), Direct method by program |
Number of instructions |
Basic |
30 |
Application |
218 |
Processing speed |
0.5㎲/Step |
Program memory capacity |
7Ksteps |
Memory device |
P (I/O Relay) |
P0000~P31F (512 points) |
M (Auxiliary relay) |
M0000~M191F (3,072 points) |
K (Keep relay) |
K0000~K031F (512 points) |
L (Link relay) |
L0000~L063F (1,024 points) |
F (Special relay) |
F000~F063F (1,024 points) |
T (Timer) |
100ms |
T000~T191 (192 points) |
10ms |
T192~T255(64 points) |
C (Counter) |
C000~C255 (256 points) |
S (Step controller) |
S00.00~S99.99 (100 x 100) |
D (Data register) |
D0000~D4999 (5,000 words) |
Timer type |
ON Delay, OFF Delay, Integration, Monostable, Retriggerable timer |
Counter type |
Up, Down, Up-Down, Ring counter |
Self-diagnosis functions |
Watchdog timer, Memory error, I/O error, Batter error, Power supply error |
Built-in special function |
PID control |
Controlled by instruction, Auto tuning, Forward/Reverse action, Forced output, Operation scan time setup |
Cnet I/F function (RS-232C) |
Dedicated protocol, MODBUS protocol, User-defined protocol |
High speed counter |
Counting speed |
1 Phase: 16kHz (1 channel) 2 Phase: 8kHz (1 channel) 3 Counting modes |
Counting method |
1Phase, up/down count with program Input 1Phase, up/down count B-phase Input 2 Phase, up/down with phase difference |
Multiplication |
1, 2 or 4 |
Pulse catch |
Pulse width : 0.2 ms, 8points |
Pulse output |
2kHz |
External interrupt |
8 points (0.4ms) |
Input filter |
0~15ms (Setting by 1ms) |
*1) K7M-DR10S (/DC), K7M-DT10S: Built-in RS-232C and RS-485 port. Simultaneous use is not allowed and a communication module is not available to use. Built-in Cnet dip switch: ON (RS-232C), OFF (RS-485)